  1. Non-Saturating, Real-Time Battlefield Dosimeter

    SBC: SPECTRAL LABS INCORPORATED            Topic: DTRA172007

    Spectral Labs proposes the development of a radiation dosimeter capable of accurately measuring both prompt and residual gamma and neutron particles without saturating at the dose rates expected from a nuclear event. The proposed dosimeter will be capable of live readout but will typically operate in a low power sleep state for extended battery life, and the dosimeter will utilize a well-tested ci ...

    SBIR Phase I 2018 Department of DefenseDefense Threat Reduction Agency
  2. Isotope Nuclear Forensics from Optical Real-time Measurements (INFORM)

    SBC: APPLIED SPECTRA INC            Topic: DTRA172008

    The SBIR Phase I effort will demonstrate the performance of an Atmospheric Pressure Glow Discharge (APGD) excitation/ionization source with Laser Ablation (LA) sampling and Optical Emission Spectroscopy (OES) for rapid field elemental and isotopic analysis of surrogate nuclear debris samples. Laser sampling mitigates the need for sample preparation or consumables. The APGD will be tested as an ato ...

    SBIR Phase I 2018 Department of DefenseDefense Threat Reduction Agency
  3. Field-Expedient Nuclear Isotope Characterization Spectrometer

    SBC: HEDGEFOG RESEARCH INC.            Topic: DTRA172008

    To address the DTRA's need for a field deployable mass spectrometer for nuclear forensic analysis (NFA), Hedgefog Research Inc. (HFR) proposes to develop a new Field-Expedient Nuclear Isotope Characterization Spectrometer (FENICS), based on species-specific ionization and novel signal enhancement schemes. New system features in FENICS will enable rapid, on-site characterization of nuclear debris s ...

    SBIR Phase I 2018 Department of DefenseDefense Threat Reduction Agency
  4. Real-Time Frequency-Selective Fading Channel Realization Generator

    SBC: WELKIN SCIENCES, LLC            Topic: DTRA122020

    During Phase I and a first Phase II, Welkin Sciences developed the Channel Realization Generator (CReG) algorithm, an enhanced functional replacement for the ACIRF code intended to be embedded into software link simulations and HWIL fading channel simulators. The proposed second Phase II effort will refine the CReG documentation and its software and firmware implementations. Many in the strategic ...

    SBIR Phase II 2018 Department of DefenseDefense Threat Reduction Agency
  5. Innovative Mitigation of Radiation Effects in Advanced Technology Nodes

    SBC: MICROELECTRONICS RESEARCH DEVELOPMENT CORPORATION            Topic: DTRA16A003

    Micro-RDC has developed portable radiation effects test structures that scale to new process nodes.These structures will enable the investigation of the effects of radiation on the new technology from the material processing level as well as the circuit level.Fabricating the chosen structures and the refinement of software to extract the model parameters will be completed in this effort.A suite of ...

    STTR Phase II 2018 Department of DefenseDefense Threat Reduction Agency
  6. Compact Laser Drivers for Photoconductive Semicond

    SBC: SCIENTIFIC APPLICATIONS & RESEARCH ASSOCIATES, INC.            Topic: DTRA16A004

    For effective protection against radiated threats, it is important to understand not only the physics of the threats, but also to quantify the effects they have on mission-critical electrical systems. Radiated vulnerability and susceptibility testing requires delivery of high peak power and peak electric fields to distant targets. The most practical solution to simulate such environments on large ...

    STTR Phase II 2018 Department of DefenseDefense Threat Reduction Agency
  7. Hierarchical, Layout-Aware, Radiation Effects Tools Vertically Integrated into an EDA Design Flow for Rad-Hard by Design

    SBC: RELIABLE MICROSYSTEMS LLC            Topic: DTRA16A003

    The goal of this workis to establish a radiation-aware capability in a commercial EDA design flow that will enable first-pass success in radiation resiliency for DoD ASIC designs in much the same way that existing EDA design suites ensure first pass functionality and performance success of complex ASICs destined for commercial applications.Such an integrated capability does not presently exist.The ...

    STTR Phase II 2018 Department of DefenseDefense Threat Reduction Agency
  8. Infectious Disease Diagnostics and Differentiation of Viral vs. Bacterial Infections for Point ofCare Applications

    SBC: GENECAPTURE, INC.            Topic: CBD15C001

    GeneCapture, Inc. is proposing to develop a rapid in vitro diagnostic prototype using our patented molecular-based CAPTURE (ConfirmActive Pathogens Through Unamplified RNA Expression) assay. Based on the results and experience gained in our Phase I STTR contractHDTRA1-16C-0061: Infectious Disease Diagnostics and Differentiation of Viral vs. Bacterial Infections for Point of Care Applications, we p ...

    STTR Phase II 2018 Department of DefenseOffice for Chemical and Biological Defense
  9. MicroLens Hyperspectral Imager for Standoff Chemical Detection

    SBC: SURFACE OPTICS CORP.            Topic: CBD171002

    A program to develop a compact, MLA-based, LWIR hyperspectral imager is proposed. The proposed Hyperspectral Chemical Imaging Sensor(HyCIS) builds upon Surface Optics real-time hyperspectral imaging activities, including our 3D full-motion video spectral imaging (FMV-SI)technology and our MIDIS hyperspectral image processor. Simultaneously sampling 16 or more spectral bands from 8 um to 12 um (MWI ...

    SBIR Phase I 2018 Department of DefenseOffice for Chemical and Biological Defense
  10. HawkEye MicroLens Hyperspectral Imager for Standoff Chemical Detection

    SBC: SA PHOTONICS, LLC            Topic: CBD171002

    SA Photonics is please to submit the proposal for the HawkEye compact LWIR hyperspectral imaging system. HawkEye leverages SA Photonicsprevious visible, SWIR, and LWIR programs to result in a compact, hand held, battery operated hyperspectral imager in a low cost designapproach. Furthermore, HawkEye will leverages SA Photonics expertise in warfighter body worn equipment and ground troop personaleq ...