You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Diver Breathing Gas Re-heater for Closed Circuit Underwater Breathing Apparatus

    SBC: Sea Star, LLC            Topic: SOCOM182003

    The objective of this proposal is to develop a robust, lightweight and compact device for re-heating and maintaining the temperature of a divers inspired breathing gas when diving on a closed circuit underwater breathing apparatus for the duration of the dive. As a solution, Simuleer proposes to develop the Hybrid Energy Abiotic Thermoelectric (HEAT) system based on a high-power hybrid (i.e. passi ...

    SBIR Phase I 2018 Department of DefenseSpecial Operations Command
  2. Photoacoustic Gasses Optical Detector and Analyzer

    SBC: Physical Optics Corporation            Topic: CBD171004

    To address the DoDs Chemical and Biological Defense (CBD) program need for the development of real-time analytical technology for multicomponent vapor identification and quantification, Physical Optics Corporation (POC) proposes to develop a new Photoacoustic Gasses Optical Detector and Analyzer (PAGODA). It is based on a new system design that utilizes a novel, POC-developed photoacoustic transdu ...

    SBIR Phase I 2017 Department of DefenseOffice for Chemical and Biological Defense
  3. MicroLens Hyperspectral Imager for Standoff Chemical Detection

    SBC: SURFACE OPTICS CORP.            Topic: CBD171002

    A program to develop a compact, MLA-based, LWIR hyperspectral imager is proposed. The proposed Hyperspectral Chemical Imaging Sensor(HyCIS) builds upon Surface Optics real-time hyperspectral imaging activities, including our 3D full-motion video spectral imaging (FMV-SI)technology and our MIDIS hyperspectral image processor. Simultaneously sampling 16 or more spectral bands from 8 um to 12 um (MWI ...

    SBIR Phase I 2018 Department of DefenseOffice for Chemical and Biological Defense
  4. HawkEye MicroLens Hyperspectral Imager for Standoff Chemical Detection

    SBC: SA PHOTONICS, LLC            Topic: CBD171002

    SA Photonics is please to submit the proposal for the HawkEye compact LWIR hyperspectral imaging system. HawkEye leverages SA Photonicsprevious visible, SWIR, and LWIR programs to result in a compact, hand held, battery operated hyperspectral imager in a low cost designapproach. Furthermore, HawkEye will leverages SA Photonics expertise in warfighter body worn equipment and ground troop personaleq ...

    SBIR Phase I 2018 Department of DefenseOffice for Chemical and Biological Defense
  5. Extended Release of Pyridostigmine Bromide for Effectively Combating Nerve Agent Exposure

    SBC: INNOSENSE CORPORATION            Topic: CBD181004

    Chemical warfare agents such as the lethal nerve agent soman are a major source of risk to military personnel. Currently, pyridostigmine bromide (PB) is the only FDA-approved pretreatment to counteract the effects of soman. The rationale behind PB administration is that it acts as a “temporary” inhibitor of AChE. This precludes nerve agents from irreversible inactivation of AChE, thereby mitig ...

    SBIR Phase I 2019 Department of DefenseOffice for Chemical and Biological Defense
  6. Sequential Phase II Proposal for Smartphone Application for Mask Sizing and Projecting Quantitative Fit

    SBC: Physical Optics Corporation            Topic: CBD181006

    To address the Chemical and Biological Defense (CBD) need for a field-portable mass spectrometer for small molecule drugs in clinical samples, Physical Optics Corporation (POC) proposes to develop a new FiEldable DRug Mass Analysis (FERMA) system based on a combination of portable mass spectrometry technology with laser desorption/ionization for use with aqueous clinical samples. The FERMA system ...

    SBIR Phase I 2019 Department of DefenseOffice for Chemical and Biological Defense
  7. Field-Usable Designer Drug Analyzer

    SBC: REAL-TIME ANALYZERS INC            Topic: CBD181006

    While this solicitation describes the need for better sampling methods and more rugged mass spectrometers to meet this DoD requirement, the topic author agreed to consider our alternative approach, which employs existing DoD Raman spectrometers. The goal of this proposed project (through Phase III) is to develop a Field-Usable Designer Drug Analyzer capable of identifying and quantifying drugs in ...

    SBIR Phase I 2019 Department of DefenseOffice for Chemical and Biological Defense
  8. Faster Optical Modem for Underwater Data Acquisition

    SBC: SA PHOTONICS, LLC            Topic: NGA182001

    SA Photonics’ Optical Navigation and Ranging (ONAR) system is an interrogative system that operate underwater in wavelength range of blue/green (450-540 nm) and enables navigational correction to IMU based dead reckoning navigation. The location based beacons are battery operated and have operational life span of over one year. The system is designed to operate in on demand burst mode so that no ...

    SBIR Phase I 2019 Department of DefenseNational Geospatial-Intelligence Agency
  9. Faster Optical Modem for Underwater Data Acquisition

    SBC: SONALYSTS INC            Topic: NGA182001

    To address NGA’s requirements, Sonalysts’ team of world-class experts in underwater optical communication proposes development and implementation of the Precision Optical Navigation Transceiver for Undersea Systems (PONTUS). PONTUS will transfer navigation information from an Underwater Navigation Beacon (UNB) to an Unmanned Undersea Vehicle (UUV) in an electromagnetic-spectrum-denied (e.g., G ...

    SBIR Phase I 2019 Department of DefenseNational Geospatial-Intelligence Agency
  10. A Multi-Branch Network for Automated VNIIRS Assessment of Motion Imagery

    SBC: TOYON RESEARCH CORPORATION            Topic: NGA191003

    Due to the lack of consistency in existing automated methods for assigning VNIIRS levels to motion imagery, and the overwhelming human resources required to manually assign levels, a new method of automated/semi-automated VNIIRS assessment is needed. In recent years, advancements in deep learning have provided solutions to previously intractable computer vision problems. In many cases, automated d ...

    SBIR Phase I 2019 Department of DefenseNational Geospatial-Intelligence Agency
US Flag An Official Website of the United States Government