You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. LEAD IODIDE SEMICONDUCTOR FOR NUCLEAR SENSOR

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: N/A

    LEAD IODIDE (PBI2) IS A LITTLE USED COMPOUND SEMICONDUCTOR THE HIGH ATOMIC NUMBERS OF ITS CONSTITUENT ELEMENTS GIVES ITEXTRAORDINARY PHOTOELECTRIC ABSORPTION EFFICIENCY OFOR GAMMAPHOTONS, WHILE ITS 2.5 EV BANDGAP PROMISES PERFORMANCE AT TEMPERATURES UP TO 250 DEGREES C. IT HAS SHOWN SOME PROM- ISE AS A HIGH EFFICIENCY SOLID-STATE DETECTOR, BUT EARLY DEVICES WERE LIMITED BY MATERIAL IMPURITIES AND ...

    SBIR Phase II 1988 National Science Foundation
  2. ID/OD FORCE-ADAPTIVE BEARING GRINDING

    SBC: Hahn Engineering Inc.            Topic: N/A

    A NEW METHOD FOR GRINDING THE OUTSIDE (OD) AND INSIDE DIAMETERS (ID) AT A SINGLE CLAMPING OF BEARING RINGS IS PROPOSED. SINCE MOST BEARINGS ARE MANUFACTURED IN SMALL LOT SIZES, CONSIDERABLE SET-UP TIME IS REQUIRED WHEN CHANGING TO A NEW BEARING RING. CURRENTLY, TWO MACHINES ARE NECESSARY; ONE FOR THE OD, AND ONE FOR THE ID. THIS PROPOSAL SEEKS A NEW METHOD TO HOLD THE RINGS WITHOUT DISTORTING THEM ...

    SBIR Phase II 1988 National Science Foundation
  3. A NOVEL CONDUCTIVE, REDOX PLYMER FOR BATTERY AND OTHER APPLICATIONS

    SBC: EIC LABORATORIES, INC.            Topic: N/A

    THE SYNTHESIS AND EVALUATION OF A CONDUCTIVE, REDOX POLYMER IS PROPOSED FOR USE AS AN ELECTRODE MATERIAL FOR RECHAREABLEAQUEOUS AND NON-AQUEOUS BATTERIES. IN AN ELECTRODE, THIS POLYMER WOULD BE CAPABLE OF RAPID AND REVERSIBLE ELECTROCHEMISTRY WITHOUIT THE USE OF METALS. THE POLYMER ALSO HAS A LOW EQUIVALENT WEIGHT ALLOWING FOR HIGH CHARGE DENSITY ELECTRODES. THE PLLYMER MAY FIND ADDITIONAL APPLICA ...

    SBIR Phase II 1988 National Science Foundation
  4. VERY HIGH SENSITIVITY SPECTROMETER FOR ATMOSPHERIC MEASUREMENTS

    SBC: SOUTHWEST SCIENCES INC            Topic: N/A

    THE ACCURATE MEASUREMENT OF CONCENTRATIONS OR FLUXES OF TRACE GASES IN THE ATMOSPHERE IS CRUCIAL TO MANY AREAS OF ATMOSPHERIC RESEARCH. INSTRUMENTATION BASED ON TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY HAS WIDE GENERALITY FOR DETECTION OF MANY ATMOSPHERIC SPECIES. TO DATE, HOWEVER, SUCH SYSTEMS HAVE USUALLY BEEN BULKY AND AWKWARD TO OPERATE AND DO NOT HAVE ADEQUATE SENSITIVITY FOR THE MEASUREME ...

    SBIR Phase II 1988 National Science Foundation
  5. A PORTABLE IMAGING SYSTEM FOR NONDESTRUCTIVE EXAMINATION OF NUCLEAR POWER PLANT COMPONENTS

    SBC: TPL, INC            Topic: N/A

    THE DIFFICULTY IN PREDICTING STRUCTURAL DEGRADATION RATES FOR NUCLEAR POWER PLANT COMPONENTS DUE TO CORROSION AND OTHER FACTORS HAS LED TO THE NEED FOR COSTLY, TIME CONSUMING INSPECTIONS AND INCREASED COST FROM INTENTIONALLY OVERDESIGNED COMPONENTS. THE SITUATION INDICATES A SERIOUS, UNMET NEED FOR A SIMPLE BUT ACCURATE SYSTEM FOR REAL- TIME, IN SITU, NONDESTRUCTIVE ANALYSIS OF NUCLEAR POWER PLANT ...

    SBIR Phase II 1994 Nuclear Regulatory Commission
  6. Inservice Diagnostics of Motor Operated Valves

    SBC: ACENTECH INCORPORATED            Topic: N/A

    N/A

    SBIR Phase II 1996 Nuclear Regulatory Commission
  7. SPECIAL MONITOR DETECTOR DEVELOPMENT FOR RESPIRATOR CONTAMINATION

    SBC: Shonka Research Associates            Topic: N/A

    IMPLEMENTATION OF AN INTEGRATED DETECTION SYSTEM FOR CONTAMINATION MONITORING OF RESPIRATORS HAS BEEN PROBLEMATIC. BECAUSE OF THE COMPLEX SURFACES, HAND MONITORING USING PORTABLE SURVEY INSTRUMENTATION HAS BEEN THE PREFERRED METHOD. HAND MONITORING IS COSTLY IN TIME AND OFTEN FAILS TO RELIABLY ACHIEVE A GIVEN DETECTION LIMIT BECAUSE OF VARIABLES SUCH AS SURVEY SPEED ANDDISTANCE FROM THE PROBE. THE ...

    SBIR Phase II 1994 Nuclear Regulatory Commission
  8. COUPLED HIGH PERFORMANCE LIQUID CHROMATOGRAPHY WITH FOURIER TRANSFORM INFRARED SPECTROSCOPY INSTRUMENTATION FOR THE CHARACTERIZATION OF POLYMERS

    SBC: Laboratory Connections Inc.            Topic: N/A

    THIS PROJECT DEVELOPS HYPHENATED LC-IR TECHNOLOGY THAT PROVIDES A MARKED ADVANCE OVER CONVENTIONAL CHROMATOGRAPHY/IR SPECTROSCOPY ANALYTIC METHODS. THE APPARATUS IS COUPLED WITH A COMPUTER SOFTWARE PACKAGE THAT AIDS IN THE ANALYSIS OF THE COMPLEX DATA SETS. AS PART OF THIS PROJECT, THE APPARATUS AND SOFTWARE ARE BEING APPLIED TO THE CHARACTERIZATION OF POLYMER SAMPLES THAT DEMONSTRATE THE CAPABI ...

    SBIR Phase II 1997 National Science Foundation
  9. A Detection System for Determining the Concentration, Size, and Depth of Buried Radioactive Material

    SBC: Shonka Research Associates            Topic: N/A

    N/A

    SBIR Phase II 1996 Nuclear Regulatory Commission
  10. DEVELOPMLENT OF A LAUNDRY MONITOR FOR DETECTION OF HOT PARTICLE CONTAMINATION

    SBC: Shonka Research Associates            Topic: N/A

    TWO APPROACHES WILL BE EXAMINED TO SIGNIFICANTLY IMPROVE THESENSITIVITY OF LAUNDRY MONITORS TO DETECT AND SPECIFY LOCATION OF HOT PARTICLES ON LAUNDERED GARMENTS. THESE PROPOSED TECNIQUES HAVE HIGH POTENTIAL FOR DETECTING BOTH LOW ENERGY BETA AND ALPHA PARTICLE RADIATION AS WELL AS IMPROVING SENSITIVITY BY REDUCING BACKGROUND COUNT RATE.

    SBIR Phase II 1990 Nuclear Regulatory Commission
US Flag An Official Website of the United States Government