You are here
Development of bioactive surface for pediatric hemodialysis catheters to prevent thrombogenic inflammatory and biofilm complications
Phone: (412) 828-5209
Email: ahussain@ension.com
Phone: (412) 828-5209
Email: mgartner@ension.com
DESCRIPTION provided by applicant The most common hemodialysis catheter complications are thrombosis inflammation and biofilms Thrombotic deposition and inflammation have been shown to result in inadequate dialysis and lead to higher complication rates and increased mortality and can take many different forms including isolated clots thrombosis in vessels adjacent to the catheter tip or fibrin sheaths formed within the catheter lumen The situation in pediatric dialysis is even more woeful because pediatric catheters are a smaller caliber with lower blood flow rates making them particularly prone to thrombosis and catheter complications The fundamental mechanism initiating the catheter related complications is the bodyandapos s inherent non specific immune response to contact with foreign materials When a foreign object such as a catheter is inserted into the patientandapos s circulation the immediate foreign body response is the adsorption of circulating proteins onto the catheterandapos s surface including thrombin tissue factor and complement C a C a Adsorption directs conformational changes to the proteins that expose normally hidden epitopes activating inflammatory cells such as monocytes and platelets that leads to thrombosis In addition dialysis patients have compromised immune systems with additional stores of mitogens that induce a hyper reaction to foreign surfaces Therefore it is vital to have a catheter surface that
mitigates the foreign body response and prevents chronic inflammation and thrombosis This objective of this proposal is to develop and evaluate the efficacy of a novel surface inspired by the naturally occurring endothelial glycocalyx The proposed bioactive surface will minimize the thrombogenic and inflammatory potential of the most commonly used pediatric hemodialysis catheter Split CathTM MedComp thus preventing chronic inflammation and minimizing thrombosis The surface modification Specific Aim consists of four steps Cleaning of the polycarbonate polyurethane catheter surface to provide a consistent stable surface for subsequent modifications Activation by plasma enhanced vapor deposition to generate active sites to which the hydrogel can be grafted Grafting of a hydrogel via free radical polymerization to the activated surface Coupling of bioactive heparin Each of the steps will
be individually evaluated and subsequent steps will not be attempted until acceptance criteria are met Blood perfusion studies Specific Aim will be used to evaluate surfaces that meet Specific Aim acceptance criteria Tested surfaces will be evaluated for protein cell adherence and cellular activation in the circulating blood Surfaces meeting in vitro acceptance criteria specified in Specific Aim will be evaluated in a day rat model Specific Aim Nine control and nine surface treated catheters will be evaluated using a cm segment catheter surface treated or control placed in the superior vena cava The efficacy of the surface on the implanted catheters will be assessed by Immunohistochemical analysis of the tissue surrounding the catheter Scanning electron microscopy SEM on the cellular layer biofilm on the catheter Flow cytometry of blood samples to quantify white cell and platelet activation and thrombogenesis
PUBLIC HEALTH RELEVANCE The most common hemodialysis catheter complications are thrombosis inflammation and biofilms Thrombotic deposition and inflammation have been shown to result in inadequate dialysis and lead to higher complication rates and increased mortality and can take many different forms including isolated clots thrombosis in vessels adjacent to the catheter tip or fibrin sheaths formed within the catheter lumen The situation in pediatric dialysis is even more woeful because pediatric catheters are a smaller caliber with lower blood flow rates making them particularly prone to thrombosis and catheter complications The goal of the proposed SBIR effort is to develop and evaluate a novel non thrombogenic and non fouling surface for pediatric hemodialysis catheters to reduce thrombosis and inflammation complications The proposed surface will prevent protein and cellular adsorption on the surface which will minimize the activation of inflammatory and thrombogenic cascades
* Information listed above is at the time of submission. *