Rodent Centrifuge

Award Information
Agency: National Aeronautics and Space Administration
Branch: N/A
Contract: NNX17CA55P
Agency Tracking Number: 174230
Amount: $124,912.00
Phase: Phase I
Program: SBIR
Solicitation Topic Code: H8.01
Solicitation Number: N/A
Timeline
Solicitation Year: 2017
Award Year: 2017
Award Start Date (Proposal Award Date): 2017-06-09
Award End Date (Contract End Date): 2017-12-08
Small Business Information
7200 Highway 150, Greenville, IN, 47124-9515
DUNS: N/A
HUBZone Owned: N
Woman Owned: N
Socially and Economically Disadvantaged: N
Principal Investigator
 John Vellinger
 Vice President & COO
 (812) 923-9591
 jvellinger@techshot.com
Business Contact
 John Vellinger
Title: Business Official
Phone: (812) 923-9591
Email: jvellinger@techshot.com
Research Institution
N/A
Abstract
According to the decadal report titled, Life and Physical Sciences Research for a New Era of Space Exploration, a Report, ??the AHB Panel would be remiss if it did not strongly recommend an animal centrifuge capable of accommodating rats/mice at variable gravity levels.? Furthermore, the panel stated, ??research on animal models will be constrained without the ability to manipulate the gravity variable as a factor modulating the fundamental processes underlying organ system homeostasis.? In response, Techshot has proposed to develop a Rodent Centrifuge Facility (RCF-QL) that utilizes four locker locations (Quad Locker) in the EXPRESS Rack for life science research. The counter-balanced centrifuge is designed to provide a facility to allow rats and mice to live and be observed in simulated gravity between 0-1 g for up to 90 days. The RCF-QL provides up to five cages. Each cage can accommodate at least six 30 gram mice, three 200 gram rats, or two 400 gram rats per cage. Each individual cage has ablib food and water, controllable lighting, and video monitoring. The habitat is temperature controlled with constant airflow throughout the cages. Air flow entraps waste in a filter that also treats the waste for bacteria and odor. Additional air filters will remove odors and ammonium from the animal enclosure. The subsystems design will minimize crew time. Each subsystem requiring change-out during the 90 day experiment will be designed to be simple and intuitive in operations. The RCF-QL will be the only facility capable of providing group housing for rats and mice, with a medium diameter centrifuge (20 in., 0.508 m) and a large rotating cage volume (1000 in3, 16,400 cm3 for the cage). All hardware cage features are designed to meet NIH animal care and use standards.

* Information listed above is at the time of submission. *

Agency Micro-sites

SBA logo
Department of Agriculture logo
Department of Commerce logo
Department of Defense logo
Department of Education logo
Department of Energy logo
Department of Health and Human Services logo
Department of Homeland Security logo
Department of Transportation logo
Environmental Protection Agency logo
National Aeronautics and Space Administration logo
National Science Foundation logo
US Flag An Official Website of the United States Government