Homogeneous Mutation Scanning

Award Information
Agency: Department of Health and Human Services
Branch: N/A
Contract: 4R42GM072419-02
Agency Tracking Number: GM072419
Amount: $750,000.00
Phase: Phase II
Program: STTR
Awards Year: 2005
Solitcitation Year: N/A
Solitcitation Topic Code: N/A
Solitcitation Number: N/A
Small Business Information
Idaho Technology
390 Wakara Way, Salt Lake City, UT, 84108
Duns: N/A
Hubzone Owned: N
Woman Owned: N
Socially and Economically Disadvantaged: N
Principal Investigator
 CARL WITTWER
 (801) 581-4737
 CARL.WITTWER@PATH.UTAH.EDU
Business Contact
 MONTY BOTOSAN
Phone: (801) 582-5138
Email: MONTY@IDAHOTEC.COM
Research Institution
N/A
Abstract
DESCRIPTION (provided by applicant): Our objective is to provide a homogeneous, closed-tube system for DNA mutation scanning on a high-throughput platform. For many complex genetic diseases, it is very difficult and expensive to screen for all possible mutations that may cause the disease. We propose a relatively simple solution. Certain dyes are compatible with PCR and can detect sequence alterations present in one copy of DNA by simple melting analysis after amplification. The dye is added before PCR, and optionally followed in real-time during amplification. Heterozygotes are easily identified after a 5 min. high-resolution melting curve after PCR. Specific aims for Phase I of this Fast Track proposal include: 1. Identify and/or synthesize scanning dyes that can be used with standard fluorescein optics. 2. Demonstrate that heterozyotes can be identified by high-resolution melting on a 384-well platform. 3. Achieve 90% sensitivity and specificity for single base change heterozygote detection in PCR products up to 300 bps in length. Our currently manufactured 384-well, low-resolution genotyping instrument will be modified for high-resolution scanning. A robust DNA scanning dye for use with standard fluorescein optics will be identified and/or synthesized for this instrument and potentially others. A comprehensive screen of single base mismatches in engineered plasmids will be used to establish the sensitivity and specificity of the system, and provide the criteria for Phase II funding. Advantages of high-resolution melting analysis for mutation scanning include speed (< 5 min), homogeneous design (no need for automation), closed-tube analysis (no amplicon contamination risk), and sample disposition (immediately available for sequencing if necessary).

* information listed above is at the time of submission.

Agency Micro-sites

US Flag An Official Website of the United States Government