Implantable glucose sensor with prolonged accuracy

Award Information
Agency: Department of Health and Human Services
Branch: N/A
Contract: 2R44DK074243-02A2
Agency Tracking Number: DK074243
Amount: $806,213.00
Phase: Phase II
Program: SBIR
Awards Year: 2008
Solicitation Year: 2008
Solicitation Topic Code: N/A
Solicitation Number: PHS2007-2
Small Business Information
MC3, INC., 3550 W LIBERTY RD, STE 3, ANN ARBOR, MI, 48103
DUNS: 806687406
HUBZone Owned: Y
Woman Owned: Y
Socially and Economically Disadvantaged: Y
Principal Investigator
 MELISSA REYNOLDS
 (734) 995-9089
 REYNOLDS@MC3CORP.COM
Business Contact
Phone: (734) 995-9089
Email: koster@mc3corp.com
Research Institution
N/A
Abstract
DESCRIPTION (provided by applicant): The goal of this study is to fabricate an intravascular glucose sensor that functions accurately for 7 days in vivo. We will utilize a glucose membrane design devised in Phase I to develop a custom outer membrane that has covalently attached bioactive sites to resist biofouling, allows for suitable glucose diffusion, and prevents leaching of potentially toxic by-products. This membrane will be applied to needle-type, amperometric glucose sensor. The versatility of the s ensor design will allow easy incorporation into a patient's bloodstream through a central access catheter. The catheter will be designed for 7 day use in the intensive care unit, and will be complete with a hemostatic connector for attaching to an access l ine, and the electrical connections to an amplifier/display unit. The final prototype will be evaluated for cytotoxicity, hemocompatibilty, and accuracy both using in vitro and in vivo methods. Continuous monitoring of blood glucose levels has been an elus ive goal, but would greatly improve the care for critically ill patients in managing insulin therapy. PUBLIC HEALTH RELEVANCE: The goal in this grant is to make an intravascular glucose sensor that measures blood glucose levels continuously for 7 days. By maintaining sensor function, this technology will provide health care professionals with immediate changes in patient health and decrease complications. Currently sudden changes in glucose levels are not detected leading to increased health care costs and increased risks to patients.

* Information listed above is at the time of submission. *

Agency Micro-sites

SBA logo
Department of Agriculture logo
Department of Commerce logo
Department of Defense logo
Department of Education logo
Department of Energy logo
Department of Health and Human Services logo
Department of Homeland Security logo
Department of Transportation logo
Environmental Protection Agency logo
National Aeronautics and Space Administration logo
National Science Foundation logo
US Flag An Official Website of the United States Government