A Novel Pediatric Pulsatile Rotary Ventricular Pump

Award Information
Agency:
Department of Health and Human Services
Branch
n/a
Amount:
$122,818.00
Award Year:
2008
Program:
SBIR
Phase:
Phase I
Contract:
1R43HL085986-01A1
Award Id:
89280
Agency Tracking Number:
HL085986
Solicitation Year:
n/a
Solicitation Topic Code:
n/a
Solicitation Number:
n/a
Small Business Information
MC3, INC., 3550 W LIBERTY RD, STE 3, ANN ARBOR, MI, 48103
Hubzone Owned:
N
Minority Owned:
N
Woman Owned:
N
Duns:
806687406
Principal Investigator:
() -
Business Contact:
() -
koster@mc3corp.com
Research Institute:
n/a
Abstract
DESCRIPTION (provided by applicant): A novel Pediatric Pulsatile Rotary Ventricular (PRVP) pump will be researched for pediatric Cardiopulmonary Bypass surgery which offers physiologic pulsatile blood flow, inherently safe management of low extracorporeal volumes, highly accurate very low flow control, and extended durability for long term cardiopulmonary support. These features address ongoing morbidity concerns due to vital organ injury in pediatric CPB patients caused by non-physiologic blood flows, exc essive hemodilution, poor cerebral blood flow, and acute injury due to equipment failure and operator error. In addition, the pediatric PRVP presents a new option for pediatric extended cardiac support. The RPVP uses a passively filled compliant pumping ch amber and operates under Starling principles, like the natural heart. The compliant pump chamber passively fills, and the pump produces a discharge flow based on the volume of fluid that is provided. A physiologic pulsatile flow is created under constant R PM conditions through a novel lengthwise variation of the pumping chamber geometry. Inherent safety advantages prevent retrograde flow, maintain safe circuit pressures, and prevent inadvertent draining of the venous reservoir. Phase I research will concent rate on designing the novel pump chamber, and validating safety and hydraulic performance on a pediatric mock loop. Computer modeling will be conducted to develop a hydraulic mock loop to simulate a one year old patient model as reported in the literature. The hydraulic mock loop will be manufactured and validated on the bench. The pump design will be tuned through iterative prototyping to generate a physiologic pulsatile flow and pressure in the patient mock loop while operating in a CPB extracorporeal loo p configuration. Comparative testing will be conducted in the hydraulic circuit with a standard pulsatile roller pump over a range of flow conditions representative of pediatric CPB and post operative ventricular support. The PRVP design will be bench test ed for verification of performance relative to durability and hemolysis. Phase II activities will focus on fabricating preproduction prototypes and conducting animal studies to verify device performance.This grant will result in the development of a novel pediatric blood pump for pediatric Cardiopulmonary Bypass surgery with extended durability to allow for long term cardiac support following surgery. Currently, no pump system of this type exists for pediatric patients so physicians have limited options whe n cardiac support post surgery is necessary.

* information listed above is at the time of submission.

Agency Micro-sites


SBA logo

Department of Agriculture logo

Department of Commerce logo

Department of Defense logo

Department of Education logo

Department of Energy logo

Department of Health and Human Services logo

Department of Homeland Security logo

Department of Transportation logo

Enviromental Protection Agency logo

National Aeronautics and Space Administration logo

National Science Foundation logo
US Flag An Official Website of the United States Government