TISSUE PERFUSION MONITOR FOR FREE-TISSUE TRANSFER

Award Information
Agency: Department of Health and Human Services
Branch: N/A
Contract: N/A
Agency Tracking Number: 11288
Amount: $50,000.00
Phase: Phase I
Program: SBIR
Solicitation Topic Code: N/A
Solicitation Number: N/A
Timeline
Solicitation Year: N/A
Award Year: 1989
Award Start Date (Proposal Award Date): N/A
Award End Date (Contract End Date): N/A
Small Business Information
401 12th Ave Ste 105, Salt Lake City, UT, 84103
DUNS: N/A
HUBZone Owned: N
Woman Owned: N
Socially and Economically Disadvantaged: N
Principal Investigator
 () -
Business Contact
Phone: () -
Research Institution
N/A
Abstract
FREE TISSUE TRANSFER HAS REVOLUTIONIZED MANY AREAS OF RECONSTRUCTIVE SURGERY. AS FREE TISSUE TRANSFER IS NOW BEING DONE ROUTINELY AT INSTITUTIONS WHERE INEXPERIENCED STAFF ARE UNABLE TO ADEQUATELY MONITOR VIABILITY, THE NEED FOR A RELIABLE METHOD TO MONITOR THE PATENCY OF MICROVASCULAR ANASTOMOSES HAS BECOME INCREASINGLY EVIDENT. ACCURATE MONITORING OF BLOOD FLOW DURING AND AFTER SURGERY IS ESSENTIAL, AND EARLY RECOGNITION OF POSTOPERATIVE VESSEL THROMBOSIS IS OF UTMOST IMPORTANCE IF REEXPLORATION IS TO PROVE SUCCESSFUL. NUMEROUS MONITORING TECHNIQUES HAVE BEEN INVESTIGATED. DIRECT MONITORS OF PERFUSION HAVE PROVEN TO BE OF LITTLE OR NO VALUE. PROBES ARE BULKY, VERY EXPENSIVE, AND REQUIRE GREAT CARE IN POSITIONING AND REMOVAL. INDIRECT MONITORS RATE AHEAD OF THE DIRECT MONITORS DUE TO LOW COST, SIMPLICITY, AND EASE OF PLACEMENT AND REMOVAL. HOWEVER, THESE MONITORS LACK THE NEEDED SPECIFICITY OF THE DIRECT MONITORS FOR MEASURING TISSUE PERFUSION. THIS PROJECT SEEKS TO PRESERVE THE SIMPLICITY AFFORDED BY INDIRECT MONITORING DEVICES, WHILE PROVIDING THE SPECIFICITYFOR TISSUE PERFUSION MEASUREMENT, BY UTILIZING A SELF-CALIBRATING TISSUE PO2/PCO2PROBE, WHICH MANIPULATES THE LOCAL TISSUE GAS CONDITIONS. TISSUE PO2 AND PCO2 ARE MONITORED UNDER ALTERNATING DEPLETING AND NONDEPLETING CONDITIONS. A PHYSIOLOGICALLY BASED MATHEMATICAL RELATIONSHIP RELATES TISSUE PERFUSION TO THE PO2 AND PCO2 MEASUREMENTS. THIS RESEARCH IS DIRECTED TOWARD THE IN VIVO VALIDATION OF THE METHOD.

* Information listed above is at the time of submission. *

Agency Micro-sites

SBA logo
Department of Agriculture logo
Department of Commerce logo
Department of Defense logo
Department of Education logo
Department of Energy logo
Department of Health and Human Services logo
Department of Homeland Security logo
Department of Transportation logo
Environmental Protection Agency logo
National Aeronautics and Space Administration logo
National Science Foundation logo
US Flag An Official Website of the United States Government