CONSOLIDATED DIABETES SCREENING DEVICE

Award Information
Agency:
Department of Health and Human Services
Branch
n/a
Amount:
$100,000.00
Award Year:
2002
Program:
SBIR
Phase:
Phase I
Contract:
1R43DK061791-01
Award Id:
60836
Agency Tracking Number:
DK061791
Solicitation Year:
n/a
Solicitation Topic Code:
n/a
Solicitation Number:
n/a
Small Business Information
MICRONIX, INC., 14950 GREYHOUND CT, STE 307, CARMEL, IN, 46032
Hubzone Owned:
N
Minority Owned:
N
Woman Owned:
N
Duns:
n/a
Principal Investigator:
MARYGAUNTKLOEPFER
(317) 844-4324
MICRONIXINC@EARTHLINK.NET
Business Contact:
HANSKLOEPFER
(317) 844-4324
MICRONIXINC@EARTHLINK.NET
Research Institute:
n/a
Abstract
DESCRIPTION (provided by applicant): Of the 120 million diabetics in the world, one half are undiagnosed and therefore deprived of the proven benefits of tight glucose control in curbing diabetes-related complications. Recognizing this problem the American Diabetes Association and National Diabetes Data Group advocate screening for undiagnosed diabetes to be an important health-care endeavor. Owing to its high clinical efficiency, the recommended screening test is fasting plasma glucose (FPG>110 mg/dL=impaired fasting glucose; FPG>126 mg/dL=diabetes). This applicant organization proposes to develop a compact, non-instrumented, minimally invasive and virtually painless test tab method designed to visually recognize these FPG cut-off levels. By means of a proprietary capillary architecture, the device doses and transports a blood sample in the nanoliter range to two integrated polymeric detection sites, one for the 110 mg/dL, the other for the 126 mg/dL FPG level. The detection sites embody the dry glucose reagents, as well as a composition capable of absorbing a defined volume of blood plasma while inhibiting cellular component of blood from penetrating the composition. Cellular component is wholly removed from the detection sites by proprietary chemical and physical mechanisms. This obviates the need for a separate cell filtering material, permitting an exceptionally high degree of method miniaturization. Visual recognition of the two cut-off levels is accomplished by a proprietary enzymic redox threshold assay principle. PROPOSED COMMERCIAL APPLICATIONS: The device has the potential to identify by professional, supervised mass, and self-screening millions of undiagnosed diabetics and those with impaired glucose tolerance at risk to develop overt diabetes. Since therapeutic remedies to combat diabetic complications are well established, these people miss out on the opportunity to have their condition recognized and treated, and live healthy productive lives.

* information listed above is at the time of submission.

Agency Micro-sites


SBA logo

Department of Agriculture logo

Department of Commerce logo

Department of Defense logo

Department of Education logo

Department of Energy logo

Department of Health and Human Services logo

Department of Homeland Security logo

Department of Transportation logo

Enviromental Protection Agency logo

National Aeronautics and Space Administration logo

National Science Foundation logo
US Flag An Official Website of the United States Government