A Wide Band Reflectance - DPOAE (WR-DP) Screener

Award Information
Agency:
Department of Health and Human Services
Branch
n/a
Amount:
$1,319,900.00
Award Year:
2005
Program:
SBIR
Phase:
Phase II
Contract:
2R44DC006554-02
Agency Tracking Number:
DC006554
Solicitation Year:
2005
Solicitation Topic Code:
n/a
Solicitation Number:
PHS2005-2
Small Business Information
MIMOSA ACOUSTICS
Mimosa Acoustics, 60 Hazelwood Dr, Ste 209, Champaign, IL, 61820
Hubzone Owned:
N
Socially and Economically Disadvantaged:
Y
Woman Owned:
Y
Duns:
n/a
Principal Investigator:
PATRICIA JENG
(217) 367-9740
PSJ@AUDITORYMODELS.ORG
Business Contact:
PATRICIA JENG
(217) 367-9740
PSJ@AUDITORYMODELS.ORG
Research Institution:
n/a
Abstract
DESCRIPTION (provided by applicant): The goal of newborn hearing screening is to identity infants with inner ear pathology (IEP), but most neonates who fail screening have conductive disorders (CD) rather than IEP, resulting in high false positive rates and costly follow-up diagnostic evaluation. The Rhode Island study (1993) has shown that the prevalence of conductive disorders (CD) over inner ear pathologies (IEP) to be 17 vs. 3-to-6 per 1000. While in N1CU the prevalence of CD over IEP rises to 36 vs. 23 per 1000. The ramifications of IEP and CD are different, so an accurate typing of the loss at the time of a newborn hearing screening is essential. The main objective of this proposal is to build a hearing-screening device that combines wideband reflectance measurement with DPOAE measurement into one system, where the former provides diagnostic evaluation for CD and the latter provides diagnostic evaluation for the IEP Thus in one test; both the conductive path and cochlear status are evaluated. Since both the reflectance measurement and the DPOAE measurement require an identical calibration step, the extra time needed to perform hearing screening, using the combined screening device, will be no more than few minutes. The benefit of the expected outcome is reduced false-positive rates, reduces follow up diagnostic costs, and reduced parental concern in the case of false positives. An important auxiliary benefit of the probe impedance, obtained by the reflectance measurement, is to allow for a direct estimate of the signal intensity level in the ear canal so as to mitigate the standing wave problem in the audiometric measurement. In conjunction with DPOAE measurement, the WR-DP screener will provide more accurate measurement above 3 kHz where standing wave problem occurs. The specific aims of Phase II are (1) to complete the development of the wideband reflectance-distortion product otoacoustic emission (WR-DP) screening device, toward improving its efficiency, reliability and ease of use; (2) to perform clinical studies, to obtain baseline data for the WR-DP screener, and (3) to demonstrate the diagnostic capabilities and cost effectiveness of the WR-DP screener.

* information listed above is at the time of submission.

Agency Micro-sites

US Flag An Official Website of the United States Government