Abstract
Ambient particulate matter (PM) mass exposure is determined by collecting the PM on a sample filter over a period of 24 hours. Because the composition of ambient PM is constantly changing, the PM mass measured using the reference method may not be representative of the PM levels in the atmosphere, primarily due to the loss of collected semi-volatile material that is present in the atmosphere during the collection period. In addition, by obtaining a single value over a 24-hour period, the method may not properly recognize the true exposure risks that occur during short term spikes in the ambient PM levels. Rupprecht & Patashnick Co., Inc. (R&P) proposes to resolve these issues through the use of an innovative advance to their popular TEOM¿ Ambient Particulate Monitor. The TEOM¿ mass monitor is a filter-based, inertial micro-balance that provides direct mass measurements of the collected material in near real time. The innovation, the Differential TEOM¿ System, is a self-referencing system that utilizes an electrostatic precipitator (ESP) to periodically remove the ambient PM from the sample stream to allow the system to measure sampling artifacts caused by the presence of semi-volatile compounds such as ammonium nitrate or semi-volatile organics. The Phase I research project compared the results obtained using the initial prototype Differential TEOM¿ monitor operating at ambient temperature with results from an early test Differential TEOM¿ monitor operating at a fixed control temperature and with reference method results, with all samples collected at R&P's facilities in Albany, NY. The real-time comparison showed that the performance of the ambient Differential TEOM¿ monitor accurately reflects the mass concentration measured using the other sample methods.

* information listed above is at the time of submission.

Agency Micro-sites


SBA logo

Department of Agriculture logo

Department of Commerce logo

Department of Defense logo

Department of Education logo

Department of Energy logo

Department of Health and Human Services logo

Department of Homeland Security logo

Department of Transportation logo

Enviromental Protection Agency logo

National Aeronautics and Space Administration logo

National Science Foundation logo
US Flag An Official Website of the United States Government