SANTEC SYSTEMS, INC.

Company Information

Company Name
SANTEC SYSTEMS, INC.
Address
2924 Malmo Drive
Arlington Heights, IL, -
Phone
n/a
URL
http://WWW.SANTECSYSTEMS.COM
DUNS
609259429
Number of Employees
12

Award Totals

PROGRAM/PHASE
AWARD AMOUNT ($)
NUMBER OF AWARDS
SBIR Phase I
$946,095.00
13
SBIR Phase II
$2,008,922.00
4
STTR Phase I
$179,902.00
2
Chart code to be here

Award List

  1. A new method of monitoring HIFU transducer acoustic output

    Amount: $115,254.00

    DESCRIPTION (provided by applicant): The objective of this project is to use a 2D area detector called Acousto-Optic (AO) sensor to provide an acoustic output monitoring method for HIFU transducers, w ...

    SBIR Phase I 2010 Department of Health and Human Services
  2. ACOUSTOGRAPHIC BREAST IMAGING

    Amount: $49,536.00

    THE LONG-TERM OBJECTIVE OF THIS PROJECT IS TO DEVELOP ACOUSTOGRAPHY, A NEW IMAGING METHOD, TO AID IN THE DETECTIONAND CHARACTERIZATION OF BREAST CANCER. ACOUSTOGRAPHY USES ULTRASOUND TO PRODUCE FULL-F ...

    SBIR Phase I 1990 Department of Health and Human Services
  3. NEW LIQUID CRYSTAL MATERIALS FOR BREAST CANCER IMAGING

    Amount: $299,970.00

    LIQUID CRYSTAL MATERIALS HAVE BEEN INVESTIGATED IN THE PAST FOR DETECTING AND VISUALIZING ULTRASOUND IMAGES. HOWEVER, BECAUSE OF THEIR LIMITED DETECTION SENSITIVITY, THE RESULTING "ACOUSTO-OPTICAL" DI ...

    SBIR Phase II 1995 National Science Foundation
  4. Ultrasound Exposimetry Using Liquid Crystal Plates

    Amount: $49,950.00

    Liquid crystal-based sonosensitive plates will be investigated for rapid determination of spatial distributions of temporal average intensities for diagnostic ultrasound beams, including real-time ima ...

    SBIR Phase I 1993 Department of Health and Human Services
  5. A New Liquid Crystal Detector for Underwater Acoustic/Optical Imaging

    Amount: $99,752.00

    A new liquid crystal based detector (acousto-optic sensor) will be developed for operation at frequencies below 500kHkz. The superior acoustic detection sensitivity of the sensor will be demonstrated ...

    SBIR Phase I 1997 Office of the Secretary of DefenseDepartment of Defense
  6. New Acousto-Optic Sensors for Real Time Full Field Acoustic Inspection

    Amount: $99,861.00

    New Acousto-Optic (AO) sensors will be produced that will 1) offer at least a 5x increase in the field-of-view of current AO sensors and 2) cover a wide range of frequencies (500kHz-l5MHz). Phase I wo ...

    SBIR Phase I 1998 ArmyDepartment of Defense
  7. Life Cycle Management of Aging Aircraft Based on Integrated QNDE and Reliability Assessment

    Amount: $100,000.00

    N/A

    STTR Phase I 1999 Air ForceDepartment of Defense
  8. N/A

    Amount: $0.00

    N/A

    SBIR Phase I 2000 ArmyDepartment of Defense
  9. N/A

    Amount: $749,962.00

    N/A

    SBIR Phase II 2000 ArmyDepartment of Defense
  10. New Liquid Crystal Based Acoustic Detectors and Underwater Acoustic Imaging Camera

    Amount: $0.00

    In this project, new liquid crystal materials will be developedto achieve significant improvements in the acosutic detectionsensitivity and transient response of present liquid crystalbased acoustic d ...

    SBIR Phase I 2002 NavyDepartment of Defense

Agency Micro-sites


SBA logo

Department of Agriculture logo

Department of Commerce logo

Department of Defense logo

Department of Education logo

Department of Energy logo

Department of Health and Human Services logo

Department of Homeland Security logo

Department of Transportation logo

Enviromental Protection Agency logo

National Aeronautics and Space Administration logo

National Science Foundation logo
US Flag An Official Website of the United States Government