SBIR Phase I: Development Of A Novel Composite Material Based On Monodisperse Glass Microspheres For Thermal Neutron Scintillation Detectors

Award Information
Agency:
National Science Foundation
Branch
n/a
Amount:
$149,961.00
Award Year:
2011
Program:
SBIR
Phase:
Phase I
Contract:
1045836
Award Id:
n/a
Agency Tracking Number:
1045836
Solicitation Year:
2010
Solicitation Topic Code:
NM
Solicitation Number:
n/a
Small Business Information
Nucsafe, Inc. (Currently Nucsafe)
601 Oak Ridge Turnpike, Oak Ridge, TN, 37830-7040
Hubzone Owned:
N
Minority Owned:
N
Woman Owned:
N
Duns:
120645721
Principal Investigator:
Kenneth Weston
(865) 425-8917
kweston@nucsafe.com
Business Contact:
Kenneth Weston
PhD
(865) 425-8917
kweston@nucsafe.com
Research Institution:
Stub




Abstract
This Small Business Innovation Research Phase I project will develop the technology needed for high performance neutron detectors that use Ce3+ activated 6Li glass in the form of monodisperse microspheres with strategically controlled dimensions and architecture. Current Ce3+/6Li glass scintillator technology has the potential to produce neutron detectors that are extremely sensitive, rugged, flexible in design geometry, have a large dynamic range (background to 10 Mcps), and do not contain toxic or regulated materials, but the glass also scintillates in response to gamma radiation, which is problematic since it can cause unacceptably high false neutron alarms. The proposed material to be developed will have significantly lower gamma sensitivity as compared to the bulk glass or optical fibers and will lead to a transformational impact on the performance that can be achieved as compared to existing neutron detection systems. The broader impact/commercial potential of this project includes filling a market need that is vitally important for the security of vulnerable nuclear weapons and materials, and for the prevention of illicit trafficking of these materials. The effectiveness of detection systems at high-risk border crossings, airports and seaports, as well as at nuclear weapons and components storage locations and research reactors, will be improved. Since neutrons are not emitted by most radionuclides used for medical or industrial purposes, the detection of neutrons is usually an unambiguous indicator of the presence of special nuclear materials (SNMs). Because the vast majority of neutron detection systems in existence today rely on 3He proportional counters and there is currently a global shortage of 3He, a suitable alternative neutron detection technology is urgently needed.

* information listed above is at the time of submission.

Agency Micro-sites


SBA logo

Department of Agriculture logo

Department of Commerce logo

Department of Defense logo

Department of Education logo

Department of Energy logo

Department of Health and Human Services logo

Department of Homeland Security logo

Department of Transportation logo

Enviromental Protection Agency logo

National Aeronautics and Space Administration logo

National Science Foundation logo
US Flag An Official Website of the United States Government