Bedside monitoring of endotracheal tube position

Award Information
Agency:
Department of Health and Human Services
Branch
n/a
Amount:
$402,986.00
Award Year:
2012
Program:
SBIR
Phase:
Phase I
Contract:
1R43HL112374-01A1
Award Id:
n/a
Agency Tracking Number:
R43HL112374
Solicitation Year:
2012
Solicitation Topic Code:
NHLBI
Solicitation Number:
PA11-096
Small Business Information
4079 Conway Place Circle, Orlando, FL, 32812-7988
Hubzone Owned:
N
Minority Owned:
N
Woman Owned:
N
Duns:
35035521
Principal Investigator:
HANSEN MANSY
(847) 332-2217
hamansy@msn.com
Business Contact:
HANSEN MANSY
(847) 332-2217
hamansy@msn.com
Research Institution:
Stub




Abstract
DESCRIPTION (provided by applicant): The objective of this project is to develop an innovative, accurate, and low-cost technology for bedside continuous (vs. intermittent) monitoring of endotracheal tube (ETT) positioning. The new ETT malposition detector(ET-MD) uses automated analysis of breath sounds and will be able to detect bronchial intubation and extubation (tube slippage into the bronchus or out of the trachea, respectively). Broncheal intubation may occur due to tube manipulation or patient movement and may lead to significant hypoxia and atelectasis (and possibly barotrauma and pneumothorax of the ventilated lung). Although extubation may become clinically apparent after some time, instant recognition can help avoid hypoxia. The ET-MD operation exploits the physics principle of the dependence of breath sounds on lung ventilation. There are two essential ET-MD components: 1) Acoustic sensors and 2) Computational and display module that analyzes acoustic signals and reports relevant metrics indicative of ETT location. We propose to construct and test a prototype under likely use conditions. Here, effects of room noise, adventitious sounds, and sensor positioning errors will be investigated in animals. In addition, the device will be tested in human subjects with and without pulmonary conditions and obesity. Key words: (8 maximum) Acoustics, endotracheal tube, intubation, malpositioning, breath sounds, diagnosis. PUBLIC HEALTH RELEVANCE: This project proposes to develop a device to help improvemonitoring of endotracheal tubes used in patients with ventilatory failure, airway compromise, and/or during general anesthesia. It will alert health care providers to tube malposition. This wil likely allow improved early correction of tube position, which would result in reduced morbidity, mortality and cost of healthcare.

* information listed above is at the time of submission.

Agency Micro-sites


SBA logo

Department of Agriculture logo

Department of Commerce logo

Department of Defense logo

Department of Education logo

Department of Energy logo

Department of Health and Human Services logo

Department of Homeland Security logo

Department of Transportation logo

Enviromental Protection Agency logo

National Aeronautics and Space Administration logo

National Science Foundation logo
US Flag An Official Website of the United States Government